20-100W Single Phase
Slimline Power Supplies
Key Features
- Universal AC Input / Full Range
- NEC class 2 / LPS compliant (Only selected models; see data sheet at altechcorp.com)
- LED indicator for power on
- 100% full load burn-in test
- 3 year warranty
- Input voltage range: 85-264V AC, 120-370V DC
- AC inrush current (typical):
- Cold start: 20A at 115V AC, 40A at 230V DC
- DC adjustment range (typical): +/-10% rated output voltage
- Overload protection (typical): 105%-160% constant current limiting, auto-recovery
- Over-voltage protection (typical): 115%-135% rated output voltage
- Setup, rise, time (typical): 500ms, 30ms/230V AC, 10000ms, 30ms/115V AC,at full load
- Withstand voltage: I/P-O/P:3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC
- Working temperature: -20 to +70 deg.C (-4 to +158 deg.F), refer to output derating curve
- Safety standards: UL508, EN60950-1*
- EMC standards:
- EN55022 class B,
- EN61000-4-2,3,4,5,6,8,11,
- ENV50204, EN55024, EN61000-6-1,
- EN61204-3 Light Industry Level**, criteria A
- Military Standard: MIL-HDBK-217F
|
|
30-60W
Single Phase Low Profile
Power Supplies
Key Features
- Cooling by free air convection
- Universal AC Input / Full Range
- LED indicator for power on
- 100% full load burn-in test
- 3 year warranty
- Input voltage range: 85-264V AC, 120-370V DC
- AC inrush current (only PS-30xx):
- Cold start: 15A at 115V AC, 30A at 230V DC
- DC adjustment range:* +/-10% rated output voltage
- Overload protection:* 105%-160% constant current limiting, auto-recovery
- Over-voltage protection:* 115%-135% rated output voltage
- Setup, rise, hold up time:*
- 100ms, 30ms, 60ms at full load and 230V AC
- Withstand voltage: I/P-O/P:3KV AC, I/P-FG:1.5KV AC*
- Working temperature: -20 to +50 deg.C (-4 to +122 deg.F) at 100%, and +60 deg.C (+140 deg.F) at 80% load
- Safety standards:
- EMC standards:
- EN55022 class B
- EN61000-4-2,3,4,5,6,8,11
- ENV50204
- EN61204-3
- Military Standard: MIL-HDBK-217F
|
|
75-240W
Single Phase Power Supplies
Key Features
- Universal AC Input / Full Range or switch select
- LED indicator for power on
- 100% full load burn-in test
- 3 year warranty
- Input voltage range: 85-264V AC, 120-370V DC
- AC inrush current:
- Cold start: 20A at 115V AC, 40A at 230V AC
- DC adjustment range: +/-10% rated output voltage
- Overload voltage protection: 105%-160% constant current limiting, auto-recovery
- Over-voltage protection: 115%-135% rated output voltage
- Setup, rise, hold up time: 500ms; 70ms; 30ms at full load and 230V AC
- Withstand voltage: I/P-O/P:3KV AC, I/P-FG:1.5KV AC, O/P-PG: 0.5KV AC
- Working temperature: -20 to +50 deg.C (-4 to +122 deg.F) at 100%, and +60 deg.C (+140 deg.F) at 80% load
- Safety standards:
- EMC standards:
- EN55022 class B,
- EN61000-4-2,3,4,5,6,8,11,
- ENV50204,
- EN61204-3
- Military Standard: MIL-HDBK-217F
|
|
480W
Single Phase Power Supplies
Key Features
- Universal AC Input / Full Range or switch select
- LED indicator for power on
- 100% full load burn-in test
- 3 year warranty
- Input voltage range: 90-264V AC, 250-370V DC
- AC inrush current:
- Cold start: 27A at 115V AC, 45A at 230V AC
- DC adjustment range: +/-10% rated output voltage
- Overload voltage protection: 105%-160% constant current limiting, auto-recovery
- Over-voltage protection: 115%-135% rated output voltage
- Setup, rise, hold up time: 1200ms; 40ms; 20ms at full load at 115V AC and 230V AC
- Withstand voltage: I/P-O/P:3KV AC, I/P-FG:1.5KV AC, O/P-PG: 0.5KV AC
- Working temperature: -20 to +50 deg.C (-4 to +122deg.F) at 100%, and +60 deg.C (+140 deg.F) at 80% load
- Safety standards:
- EMC standards:
- EN55022 class B,
- EN61000-4-2,3,4,5,6,8,11,
- ENV50204,
- EN61204-3
- Military Standard: MIL-HDBK-217F
|
|
240-960W
Three Phase Power Supplies
Key Features
- Three Phase Input
- LED indicator for power on
- 100% full load burn-in test
- 3 year warranty
- Input voltage range: 340-550V AC, 480-760V DC
- AC inrush current:
- DC adjustment range: +/-10% rated output voltage
- Overload voltage protection: 105%-150% constant current limiting, auto-recovery
- Over-voltage protection: 115%-135% rated output voltage
- Setup, rise, hold up time:
- 1200ms, 40ms, 20ms @ 400V AC
- 800ms, 40ms, 40ms @ 500V AC
- full load
- Withstand voltage:
- I/P-O/P:3KV AC, I/P-FG:1.5KV AC,
- O/P-PG 0.5KV AC
- Working temperature: -20 to +70 deg.C (-4 to +158 deg.F) at 100%
- Safety standards:
- EMC standards:
- EN55022 (CISPR22),
- EN61000-4-2,3,4,5,6,8,11
- ENV50204,
- EN61204-3
- EN61000-6-2 (EN50082-2) Heavy Industrial Level, criteria A
- Military Standard: MIL-HDBK-217F
|
|
Accessories:
Power Supply Redundancy Buffer Module
PS-RDN20
is a 20A redundancy (decoupling) module for the 24V DC power system.
Containing 2 sets of 20A Oring diodes with excellent heat dissipation
deployment. PS-RDN20 give you a new option for safe connection of 1+1
redundant set-up. Not only perfectly decouple power sources from each
other as well as from the load, PS-RDN20 also provides users monitoring
signals for both input channels through the built-in relays. Since
there are no switching components inside the module, PS-RDN20 will not
arise additional EMI issues and should provide you a worry-free
application platform!
40 AMP UPS Battery Controller
PS-UPS40
is a 40A max. DC UPS (battery control) module for the 24 V DC power
system. Accompany with external batteries, it can back-up up to 40A of
current to critical loads for certain period of time depending on the
capacity of batteries. With complete monitoring signals and LED
indicators for DC BUS OK, Battery Fail, Battery Discharge and the
repeated Battery Test function to check the situation of external
batteries. Users can customize their own DC UPS system to back up
critical loads and capture the status of the whole system easily.
|
|